Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Geophys Res Lett ; 47(15): e2020GL088755, 2020 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-32999518

RESUMO

Submicrosecond (0.476 µs per frame with an exposure time of 160 ns) high-resolution (0.38 nm) time-resolved spectra of laboratory-produced lightning-like electrical discharges have been recorded for the first time within the visible spectral range (645-665 nm). The spectra were recorded with the GrAnada LIghtning Ultrafast Spectrograph (GALIUS), a high-speed imaging spectrograph recently developed for lightning research in the IAA-CSIC. Unprecedented spectral time dynamics are explored for meter long laboratory electrical discharges produced with a 2.0 MV Marx generator. The maximum electron density and gas temperature measured in a timescale of ≤0.50 µs (160 ns) were, respectively, ≃1018 cm-3 and ≃32,000 K. Overpressure in the lightning-like plasma channel, black-body dynamics, and self-absorption in spectral lines were investigated.

2.
J Geophys Res Atmos ; 120(23): 12143-12156, 2015 12 16.
Artigo em Inglês | MEDLINE | ID: mdl-27867780

RESUMO

We present three terrestrial gamma ray flashes (TGFs) observed over the Mediterranean basin by the Reuven Ramaty High Energy Solar Spectroscope Imager (RHESSI) satellite. Since the occurrence of these events in the Mediterranean region is quite rare, the characterization of the events was optimized by combining different approaches in order to better define the cloud of origin. The TGFs on 7 November 2004 and 16 October 2006 came from clouds with cloud top higher than 10-12 km where often a strong penetration into the stratosphere is found. This kind of cloud is usually associated with heavy precipitation and intense lightning activity. Nevertheless, the analysis of the cloud type based on satellite retrievals shows that the TGF on 27 May 2004 was produced by an unusual shallow convection. This result appears to be supported by the model simulation of the particle distribution and phase in the upper troposphere. The TGF on 7 November 2004 is among the brightest ever measured by RHESSI. The analysis of the energy spectrum of this event is consistent with a production altitude ≤12 km, which is in the upper part of the cloud, as found by the meteorological analysis of the TGF-producing thunderstorm. This event must be unusually bright at the source in order to produce such a strong signal in RHESSI. We estimate that this TGF must contain ∼3 × 1018 initial photons with energy >1 MeV. This is 1 order of magnitude brighter than earlier estimations of an average RHESSI TGF.

3.
Med. intensiva (Madr., Ed. impr.) ; 36(4): 294-306, mayo 2012. ilus
Artigo em Espanhol | IBECS | ID: ibc-103067

RESUMO

La ventilación mecánica es una intervención terapéutica de sustitución temporal de la función ventilatoria enfocada a mejorar los síntomas en los pacientes que sufren insuficiencia respiratoria aguda. Los avances tecnológicos han facilitado el desarrollo de ventiladores sofisticados que permiten visualizar y registrar las ondas respiratorias, lo que constituye una fuente de información muy valiosa para el clínico. La correcta interpretación de los trazados es de vital importancia tanto para el correcto diagnóstico como para la detección precoz de anomalías y para comprender aspectos de la fisiología relacionados con la ventilación mecánica y con la interacción paciente-ventilador. El presente trabajo da una orientación de cómo interpretar las curvas del ventilador mediante el análisis de trazados de presión en la vía aérea, flujo aéreo y volumen en distintas situaciones clínicas (AU)


Mechanical ventilation is a therapeutic intervention involving the temporary replacement of ventilatory function with the purpose of improving symptoms inpatients with acute respiratory failure. Technological advances have facilitated the development of sophisticated ventilators for viewing and recording the respiratory waveforms, which are a valuable source of information for the clinician. The correct interpretation of these curves is crucial for the correct diagnosis and early detection of anomalies, and for understanding physiological aspects related to mechanical ventilation and patient-ventilator interaction. The present study offers a guide for the interpretation of the airway pressure and flow and volume curves of the ventilator, through the analysis of different clinical scenarios (AU)


Assuntos
Humanos , Ventiladores Mecânicos , Respiração Artificial/métodos , Insuficiência Respiratória/terapia , Síndrome Torácica Aguda/terapia , Respiração com Pressão Positiva/métodos
4.
Med Intensiva ; 36(4): 294-306, 2012 May.
Artigo em Espanhol | MEDLINE | ID: mdl-22014424

RESUMO

Mechanical ventilation is a therapeutic intervention involving the temporary replacement of ventilatory function with the purpose of improving symptoms in patients with acute respiratory failure. Technological advances have facilitated the development of sophisticated ventilators for viewing and recording the respiratory waveforms, which are a valuable source of information for the clinician. The correct interpretation of these curves is crucial for the correct diagnosis and early detection of anomalies, and for understanding physiological aspects related to mechanical ventilation and patient-ventilator interaction. The present study offers a guide for the interpretation of the airway pressure and flow and volume curves of the ventilator, through the analysis of different clinical scenarios.


Assuntos
Respiração Artificial , Insuficiência Respiratória/fisiopatologia , Insuficiência Respiratória/terapia , Doença Aguda , Humanos , Respiração
5.
J Urol ; 142(6): 1556-7, 1989 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-2585639

RESUMO

An 18-year-old man is described with an aneurysm of the left renal artery diagnosed during study for hypertension. Medical treatment achieved control of the blood pressure. The patient voluntarily interrupted treatment 1 1/2 years after initial diagnosis but the blood pressure remained normal. Angiography at that time revealed almost complete thrombosis of the aneurysm and peripheral plasma renin activity returned to normal in contrast to the high figures registered initially (15 ng. per ml., normal values 0.51 to 2.64). The patient had normal blood pressure, received no medication and was on only a salt-free diet 1 year after this event.


Assuntos
Aneurisma/complicações , Hipertensão/etiologia , Artéria Renal , Adolescente , Aneurisma/diagnóstico por imagem , Aneurisma/fisiopatologia , Angiografia Digital , Pressão Sanguínea , Humanos , Hipertensão/diagnóstico por imagem , Hipertensão/fisiopatologia , Masculino , Cooperação do Paciente , Remissão Espontânea , Artéria Renal/diagnóstico por imagem , Trombose/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...